What needs to be done to make the group function properly?

Ferris Plastics, Inc. is a medium sized company, with an enterprise network (access, distribution
and core switches) that provides LAN connectivity from user PCs to corporate servers. The
distribution switches are configured to use HSRP to provide a high availability solution.

• DSW1 -primary device for VLAN 101 VLAN 102 and VLAN 105
• DSW2 – primary device for VLAN 103 and VLAN 104
• A failure of GigabitEthemet1/0/1 on primary device should cause the primary device to release
its status as the primary device, unless GigabitEthernet1/0/1 on backup device has also failed.
Troubleshooting has identified several issues. Currently all interfaces are up. Using the running
configurations and show commands, you have been asked to investigate and respond to the
following question.

During routine maintenance, it became necessary to shut down the GigabitEthernet1/0/1 interface
on DSW1. All other interfaces were up. During this time, DSW1 remained the active device for the
VLAN 102 HSRP group. You have determined that there is an issue with the decrement value in
the track command for the VLAN 102 HSRP group. What needs to be done to make the group
function properly?

Ferris Plastics, Inc. is a medium sized company, with an enterprise network (access, distribution
and core switches) that provides LAN connectivity from user PCs to corporate servers. The
distribution switches are configured to use HSRP to provide a high availability solution.

• DSW1 -primary device for VLAN 101 VLAN 102 and VLAN 105
• DSW2 – primary device for VLAN 103 and VLAN 104
• A failure of GigabitEthemet1/0/1 on primary device should cause the primary device to release
its status as the primary device, unless GigabitEthernet1/0/1 on backup device has also failed.
Troubleshooting has identified several issues. Currently all interfaces are up. Using the running
configurations and show commands, you have been asked to investigate and respond to the
following question.

During routine maintenance, it became necessary to shut down the GigabitEthernet1/0/1 interface
on DSW1. All other interfaces were up. During this time, DSW1 remained the active device for the
VLAN 102 HSRP group. You have determined that there is an issue with the decrement value in
the track command for the VLAN 102 HSRP group. What needs to be done to make the group
function properly?

A.
The decrement value on DSW1 should be greaterthan 5 and less than 15. 0

B.
The decrement value on DSW1 should be greaterthan 9 and less than 15.

C.
The decrement value on DSW1 should be greaterthan 11 and less than 19.

D.
The decrement value on DSWTs should be greaterthan 190 and less than 200.

E.
The decrement value on DSWTs should be greaterthan 195 and less than 205.