Which command is used to determine if a host has logged in to the Fibre Channel fabric?

Which command is used to determine if a host has logged in to the Fibre Channel fabric?

Which command is used to determine if a host has logged in to the Fibre Channel fabric?

A.
show flogi database

B.
show system fc login

C.
show npv flogi-table

D.
show npv fcns database

E.
show interface vfc X flogi

F.
show interface flogi

Explanation:
In a Fibre Channel fabric, each host or disk requires an FCID. Use the show flogi database
command to verify if a storage device is displayed in the Fabric login (FLOGI) table as in the
examples below. If the required device is displayed in the FLOGI table, the fabric login is
successful. Examine the FLOGI database on a switch that is directly connected to the host HBA
and connected ports.
Examples
The following example displays details on the FLOGI database.
switch# show flogi database
—————————————————————————
INTERFACE VSAN FCID PORT NAME NODE NAME
—————————————————————————
sup-fc0 2 0xb30100 10:00:00:05:30:00:49:63 20:00:00:05:30:00:49:5e
fc9/13 1 0xb200e2 21:00:00:04:cf:27:25:2c 20:00:00:04:cf:27:25:2c
fc9/13 1 0xb200e1 21:00:00:04:cf:4c:18:61 20:00:00:04:cf:4c:18:61
fc9/13 1 0xb200d1 21:00:00:04:cf:4c:18:64 20:00:00:04:cf:4c:18:64
fc9/13 1 0xb200ce 21:00:00:04:cf:4c:16:fb 20:00:00:04:cf:4c:16:fb
fc9/13 1 0xb200cd 21:00:00:04:cf:4c:18:f7 20:00:00:04:cf:4c:18:f7
Total number of flogi = 6.
ReferencE. http://www.cisco.com/en/US/docs/storage/san_switches/mds9000/sw/rel_2_x/sanos/command/reference/CR02_sh.html#wp1248139