What is the cause of the problem?


Customer encounters the problem as shown in the exhibit. What is the cause of the problem?


Customer encounters the problem as shown in the exhibit. What is the cause of the problem?

A.
No server was requested or received by the FLOGI database.

B.
One external link must be up for server interfaceto be up.

C.
Multiple external links must be up for the serverto come up.

D.
Internal links are down and must be up for the server interface to be up.



Leave a Reply 1

Your email address will not be published. Required fields are marked *


Jorge

Jorge

Server on downstream NPV edge switch does not login to the fabric

The server connected to the downstream NPV edge switch does not log in to the fabric.

Possible Cause

The server on the downstream NPV edge switch does not log in to the fabric, and/or you see a “waiting for FLOGI” message.

Example:

switch# show npv status

npiv is enabled

Server Interfaces:

===================

Interface: fc1/6, VSAN: 1, NPIV: No, State: Waiting for FLOGI

Solution

•Verify the configuration of both the NPV edge and core switches. If you are not running the F_Port trunking feature, then verify that there are no VSAN mismatches and that the server ports, NPV NP ports, NPIV Core F_Ports, and storage ports are all in the same VSAN and all are online.

•If the configuration is correct and you can determine where the problem might be, you can collect an Ethanalyzer trace and verify that the Fabric Login (FLOGI) frame is being received and sent to the NPIV core as a Fabric Discovery (FDISC) command.

Example Ethanalyzer trace:

switch# ethanalyzer local sniff-interface inbound-hi display-filter “!llc && !stp”
limit-captured-frames 0 write bootflash:npv-trace

Capturing on eth4

•Recreate the problem by flapping the NPV-attached server port. The trace will be written to bootflash and can be copied off the switch by using the following:

copy bootflash: ftp:

•After the trace has been copied, you can now open and verify the flow using Wireshark.

Example normal NPV login flow:

Server ——————–> FLOGI ———-> NPV Edge Switch

Fabric Login frame = FLOGI

NPV Edge Switch ——> FDISC ———-> NPIV Core Switch

Fabric DISCovery frame maps parameters from Server FLOGI

NPV Core Switch ——> Accept ———> NPV Edge Switch

NPIV Core assigns an FCID with the Accept to the FDISC from NPV Edge Switch

NPV Edge Switch ——> Accept ———> Server

Accept to original Server FLOGI with FCID assigned from NPIV Core Switch

http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/troubleshooting/guide/N5K_Troubleshooting_Guide/n5K_ts_sans.html