which components in the Enterprise manager Architecture for the Database Machine?

Which two communication methods are used by which components in the Enterprise manager
Architecture for the Database Machine?

Which two communication methods are used by which components in the Enterprise manager
Architecture for the Database Machine?

A.
SNMP traps for alerts are sent by the storage server ILOM to the storage serverMSprocess

B.
SNMP traps for alerts are sent by the storage serverMSprocess to the storage server ILOM

C.
SNMP traps for alerts are sent by the storage serverILOMto the Enterprise Manageragent.

D.
SNMP traps for alerts are sent by the storage serverMSprocess to the enterprise
Manageragent

E.
SNMP traps for alerts are sent by the storage server ILOM to the storage server RS process.

Explanation:
There are two types of server alerts that come from Oracle Exadata Storage Server:
* (A)For Integrated Lights Out Manager (ILOM)-monitored hardware components, ILOM
reports a failure or threshold exceeded condition as an SNMP trap, which is received by MS.
MS processes the trap, creates an alert for the storage server, and delivers the alert via SNMP

to Oracle Enterprise Manager 12c.
* (D)For MS-monitored hardware and software components, MS processes a failure or threshold
exceeded condition for these components, creates an alert, and delivers the alert via SNMP to
Oracle Enterprise Manager Cloud Control 12c.
Reference:Managing Oracle Exadata with Oracle Enterprise Manager 12c, Oracle White Paper



Leave a Reply 4

Your email address will not be published. Required fields are marked *


L. Zhu

L. Zhu

A is wrong. EM Agent runs remote ipmitool and SNMP calls to each node ILOM target
B is wrong. SNMP does not send from MS to ILOM
C is right. EM Agent runs remote ipmitool and SNMP calls to each node ILOM target
D is right. MS sends SNMP to OEM agent
E is wrong. SNMP does not send from ILOM to RS

So C.D. are correct

L. Zhu

L. Zhu

A is right. Storage Server ILOM send SNMP to MS

For compute node ILOM, EM Agent runs remote ipmitool and SNMP calls.

So A.D. are correct

Shrikant.Homkar

Shrikant.Homkar

A and D are correct as per below:

Page 10
http://www.oracle.com/technetwork/oem/exa-mgmt/exadata-mgmt-twp-1662642.pdf

For Integrated Lights Out Manager (ILOM)-monitored hardware components, ILOM
reports a failure or threshold exceeded condition as an SNMP trap, which is received by MS.
MS processes the trap, creates an alert for the storage server, and delivers the alert via SNMP
to Oracle Enterprise Manager 12c.