— Exhibit —
{primary:node0}
user@host> show configuration chassis | display inheritance
cluster {
redundancy-group 1 {
node 0 priority 200;
node 1 priority 100;
interface-monitor {
ge-0/0/12 weight 255;
ge-5/0/12 weight 255;
}}}
— Exhibit —
A customer reports that their SRX failover is not working as expected. They expected node1 to
become the primary node for the control plane when interface ge-0/0/12 failed. However, when ge-
0/0/12 failed, node0 remained the primary node. They send you the output shown in the exhibit.
What is causing this problem?
A.
The interface-monitor configuration should be applied to redundancy-group 0.
B.
The redundancy-group configuration should include the preempt parameter.
C.
The weight parameter applied to ge-5/0/12 is too high.
D.
The weight parameter applied to ge-0/0/12 is too low.