What is causing this problem?

— Exhibit — {primary:node0} user@host> show configuration chassis | display inheritance
cluster { redundancy-group 1 { node 0 priority 200; node 1 priority 100; interface-monitor {
ge-0/0/12 weight 255; ge-5/0/12 weight 255; } } } — Exhibit — A customer reports that their
SRX failover is not working as expected. They expected node1 to become the primary node
for the control plane when interface ge-0/0/12 failed. However, when ge- 0/0/12 failed,
node0 remained the primary node. They send you the output shown in the exhibit. What is
causing this problem?

— Exhibit — {primary:node0} user@host> show configuration chassis | display inheritance
cluster { redundancy-group 1 { node 0 priority 200; node 1 priority 100; interface-monitor {
ge-0/0/12 weight 255; ge-5/0/12 weight 255; } } } — Exhibit — A customer reports that their
SRX failover is not working as expected. They expected node1 to become the primary node
for the control plane when interface ge-0/0/12 failed. However, when ge- 0/0/12 failed,
node0 remained the primary node. They send you the output shown in the exhibit. What is
causing this problem?

A.
The weight parameter applied to ge-0/0/12 is too low.

B.
The interface-monitor configuration should be applied to redundancy-group 0.

C.
The redundancy-group configuration should include the preempt parameter.

D.
The weight parameter applied to ge-5/0/12 is too high.



Leave a Reply 0

Your email address will not be published. Required fields are marked *