An administrator is considering using NPIV to assign WWNs to virtual machines. Virtual machine
portability is a major concern.
Why would NPIV be inappropriate for this deployment?
A.
Virtual machines using NPIV must use DirectPath I/O.
B.
Storage vMotion is not supported using NPIV.
C.
vMotion is not supported using NPIV.
D.
Enabling NPIV requires SR-IOV supported hardware.
Explanation:
B is correct
When you use ESXi with NPIV, the following limitations apply:
NPIV does not support Storage vMotion.
https://pubs.vmware.com/vsphere-55/index.jsp?topic=%2Fcom.vmware.vsphere.storage.doc%2FGUID-474BE53E-065A-43C0-ADCA-3D676AD394AE.html
http://buildvirtual.net/determine-requirements-for-and-configure-npiv/
VMware環境でのNPIVについて
http://www.hitsumabushi.org/blog/2014/12/30/0257.html
https://pubs.vmware.com/vsphere-55/index.jsp?topic=%2Fcom.vmware.vsphere.storage.doc%2FGUID-474BE53E-065A-43C0-ADCA-3D676AD394AE.html
ESXi で NPIV を使用する場合は、次の制限事項が適用されます。
■NPIV テクノロジーは FC プロトコルの拡張であるので、FC スイッチを必要とし、直接接続の FC ディスクには使用できません。
■WWN が割り当てられている仮想マシンまたはテンプレートをクローン作成する場合、そのクローンは WWN を保持しません。
■NPIV で Storage vMotion はサポートされません。
■仮想マシンの実行中に FC スイッチの NPIV 機能を無効にしてから再度有効にすると、FC リンクに障害が発生し、I/O が停止することがあります。